Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ufc.br/handle/riufc/58795
Tipo: Artigo de Evento
Título : Some advance in the study of the deformation of the piston-cylinder unit of a pressure balance using FE models
Título en inglés: Some advance in the study of the deformation of the piston-cylinder unit of a pressure balance using FE models
Autor : Soares Júnior, Luiz
Silva Júnior, Francisco Ilson da
Lamary, Pierre Maurice Christophe
Palabras clave : Metrologia;Metrologia científica e aplicada;Medição;Calibração;Erro de medição;Precisão de medição
Fecha de publicación : 2017
Editorial : https://metrologia.org.br/wpsite/eventos/
Citación : SOARES JUNIOR, Luiz; SILVA JÚNIOR, Francisco Ilson da; LAMARY, Pierre Maurice Christophe. Some advance in the study of the deformation of the piston-cylinder unit of a pressure balance using FE models. In: CONGRESSO METROLOGIA,9º, 26 a 29 nov. 2017, Fortaleza, CE. Anais[...] Fortaleza, p.1-5, 2017.
Resumen en portugués brasileño: Previous works carried out by us were concerned by the development of axisymmetric Finite Elements (FE) in order to model metrological pressure balance. In this paper, a given pressure balance is studied. The very question is to verify if the analytical formulae, commonly used to deduce the pressure, are accurate. In particular, in the analytical approach, the piston-cylinder deformation is taking into account by the use of a global distortion coefficient obtained by tests. This approach is compared to FE calculations where local deformations are naturally considered. For the pressure balance under study, and for the model used, the relative error obtained when comparing the FE effective area and the analytical effective area is of 0.1 per cent.
Abstract: Previous works carried out by us were concerned by the development of axisymmetric Finite Elements (FE) in order to model metrological pressure balance. In this paper, a given pressure balance is studied. The very question is to verify if the analytical formulae, commonly used to deduce the pressure, are accurate. In particular, in the analytical approach, the piston-cylinder deformation is taking into account by the use of a global distortion coefficient obtained by tests. This approach is compared to FE calculations where local deformations are naturally considered. For the pressure balance under study, and for the model used, the relative error obtained when comparing the FE effective area and the analytical effective area is of 0.1 per cent.
URI : http://hdl.handle.net/2050011876/792
http://www.repositorio.ufc.br/handle/riufc/58795
Aparece en las colecciones: DEEL - Trabalhos apresentados em eventos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
2017_eve_lsoaresjunior.pdf934,16 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.