Title: Some advance in the study of the deformation of the piston-cylinder unit of a pressure balance using FE models
Title in English: Some advance in the study of the deformation of the piston-cylinder unit of a pressure balance using FE models
Authors: Soares Júnior, Luiz
Silva Júnior, Francisco Ilson da
Lamary, Pierre Maurice Christophe
Keywords: Metrologia;Metrologia científica e aplicada;Medição;Calibração;Erro de medição;Precisão de medição
Issue Date: 2017
Publisher: https://metrologia.org.br/wpsite/eventos/
Citation: SOARES JUNIOR, Luiz; SILVA JÚNIOR, Francisco Ilson da; LAMARY, Pierre Maurice Christophe. Some advance in the study of the deformation of the piston-cylinder unit of a pressure balance using FE models. In: CONGRESSO METROLOGIA,9º, 26 a 29 nov. 2017, Fortaleza, CE. Anais[...] Fortaleza, p.1-5, 2017.
Abstract in Brazilian Portuguese: Previous works carried out by us were concerned by the development of axisymmetric Finite Elements (FE) in order to model metrological pressure balance. In this paper, a given pressure balance is studied. The very question is to verify if the analytical formulae, commonly used to deduce the pressure, are accurate. In particular, in the analytical approach, the piston-cylinder deformation is taking into account by the use of a global distortion coefficient obtained by tests. This approach is compared to FE calculations where local deformations are naturally considered. For the pressure balance under study, and for the model used, the relative error obtained when comparing the FE effective area and the analytical effective area is of 0.1 per cent.
Abstract: Previous works carried out by us were concerned by the development of axisymmetric Finite Elements (FE) in order to model metrological pressure balance. In this paper, a given pressure balance is studied. The very question is to verify if the analytical formulae, commonly used to deduce the pressure, are accurate. In particular, in the analytical approach, the piston-cylinder deformation is taking into account by the use of a global distortion coefficient obtained by tests. This approach is compared to FE calculations where local deformations are naturally considered. For the pressure balance under study, and for the model used, the relative error obtained when comparing the FE effective area and the analytical effective area is of 0.1 per cent.
URI: http://hdl.handle.net/2050011876/792
http://www.repositorio.ufc.br/handle/riufc/58795
Appears in Collections:DEEL - Trabalhos apresentados em eventos

Files in This Item:
File Description SizeFormat 
2017_eve_lsoaresjunior.pdf934,16 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.