Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ufc.br/handle/riufc/69386
Tipo: Artigo de Periódico
Título : A physical study to explain response differences between the BID and FID detectors for PAHs and pesticides
Autor : Lopes, Amanda Fonsêca
Gouveia Júnior, Florêncio Sousa
Nascimento, Hélio Oliveira do
Silva, Vitor Paulo Andrade da
Barbosa, Pablo Gordiano Alexandre
Carvalho, Tecia Vieira
Nascimento, Ronaldo Ferreira do
Palabras clave : Gas chromatography;Dielectric barrier discharge ionization detector;Flame ionization detector;Density functional theory;Ionization energy
Fecha de publicación : 2022
Editorial : Journal of the Brazilian Chemical Society
Citación : NASCIMENTO, R. F. et al. A physical study to explain response differences between the BID and FID detectors for PAHs and pesticides. Journal of the Brazilian Chemical Society, [s.l.], v. 33, n. 10, p. 1190-1199, 2022. DOI: https://dx.doi.org/10.21577/0103-5053.20220038
Abstract: The dielectric barrier discharge ionization detector (BID) is one of the most modern detectors commercially available for gas chromatography (GC). Its technology based on the sample ionization through the energy released from the helium plasma generation process gives it the ability to act as a universal detector and a greater response to various types of compounds compared to the well-established flame ionization detector (FID). In this study, polycyclic aromatic hydrocarbons (PAHs), organophosphates (OPPs) and organochlorines pesticides (OCPs) were investigated. The parameters that could explain the performance of the BID and FID detectors were: structural factors, ionization energy (IE) and energy of the highest occupied molecular orbital (EHOMO), which were obtained by density functional theory (DFT). The relative (BID/FID) responses to PAHs and pesticides were about 1.8 and 3.0 times greater than FID, respectively. Less structural dependence of the BID signal compared to the FID signal was observed. Among the parameters calculated by DFT, the IE was the one that most seemed to have influenced the response of the two detectors studied. The theoretical data proved to be quite consistent to explain the trends observed experimentally, especially to the BID.
URI : http://www.repositorio.ufc.br/handle/riufc/69386
ISSN : 0103-5053
Derechos de acceso: Acesso Aberto
Aparece en las colecciones: DEHA - Artigos publicados em revista científica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
2022_art_rfnascimento.pdf1,41 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.