Use este identificador para citar ou linkar para este item: http://repositorio.ufc.br/handle/riufc/69386
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorLopes, Amanda Fonsêca-
dc.contributor.authorGouveia Júnior, Florêncio Sousa-
dc.contributor.authorNascimento, Hélio Oliveira do-
dc.contributor.authorSilva, Vitor Paulo Andrade da-
dc.contributor.authorBarbosa, Pablo Gordiano Alexandre-
dc.contributor.authorCarvalho, Tecia Vieira-
dc.contributor.authorNascimento, Ronaldo Ferreira do-
dc.date.accessioned2022-11-22T17:34:27Z-
dc.date.available2022-11-22T17:34:27Z-
dc.date.issued2022-
dc.identifier.citationNASCIMENTO, R. F. et al. A physical study to explain response differences between the BID and FID detectors for PAHs and pesticides. Journal of the Brazilian Chemical Society, [s.l.], v. 33, n. 10, p. 1190-1199, 2022. DOI: https://dx.doi.org/10.21577/0103-5053.20220038pt_BR
dc.identifier.issn0103-5053-
dc.identifier.urihttp://www.repositorio.ufc.br/handle/riufc/69386-
dc.description.abstractThe dielectric barrier discharge ionization detector (BID) is one of the most modern detectors commercially available for gas chromatography (GC). Its technology based on the sample ionization through the energy released from the helium plasma generation process gives it the ability to act as a universal detector and a greater response to various types of compounds compared to the well-established flame ionization detector (FID). In this study, polycyclic aromatic hydrocarbons (PAHs), organophosphates (OPPs) and organochlorines pesticides (OCPs) were investigated. The parameters that could explain the performance of the BID and FID detectors were: structural factors, ionization energy (IE) and energy of the highest occupied molecular orbital (EHOMO), which were obtained by density functional theory (DFT). The relative (BID/FID) responses to PAHs and pesticides were about 1.8 and 3.0 times greater than FID, respectively. Less structural dependence of the BID signal compared to the FID signal was observed. Among the parameters calculated by DFT, the IE was the one that most seemed to have influenced the response of the two detectors studied. The theoretical data proved to be quite consistent to explain the trends observed experimentally, especially to the BID.pt_BR
dc.language.isoenpt_BR
dc.publisherJournal of the Brazilian Chemical Societypt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectGas chromatographypt_BR
dc.subjectDielectric barrier discharge ionization detectorpt_BR
dc.subjectFlame ionization detectorpt_BR
dc.subjectDensity functional theorypt_BR
dc.subjectIonization energypt_BR
dc.titleA physical study to explain response differences between the BID and FID detectors for PAHs and pesticidespt_BR
dc.typeArtigo de Periódicopt_BR
Aparece nas coleções:DEHA - Artigos publicados em revista científica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2022_art_rfnascimento.pdf1,41 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.