Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ufc.br/handle/riufc/80201
Tipo: Artigo de Periódico
Título : Design of a Dry Cover Pilot Test for Acid Mine Drainage Abatement in Southern Brazil, Part II: Pilot Unit Construction and Initial Monitoring
Autor : Soares, Anderson Borghetti
Possa, Mario Valente
Souza, Vicente Paulo de
Soares, Paulo Sérgio Moreira
Barbosa, Maria Claúdia
Ubaldo, Mariluce de Oliveira
Bertolino, Ana Valéria Freire Allemão
Borma, Laura Simone
Palabras clave en portugués brasileño: drenagem ácida de minas;fluxo de aguá;monitoramento ambiental
Palabras clave en inglés: acid mine drainage;environmental monitoring;water flow
Fecha de publicación : 2010
Editorial : Mine Water and the Environment
Citación : SOARES, A. B.; POSSA, M. V. ; SOUZA, V. P. ; SOARES, P. S. M. ; BARBOSA, M. C.; UBALDO, M. O. ; BERTOLINO, A. V. F. A.; BORMA, L. S. Design of a dry cover pilot test for acid mine drainage abatement in Southern Brazil, part II: pilot unit construction and initial monitoring. Mine Water Environ, v. 29, p. 277-284, 2010. Disponível em: https://doi.org/10.1007/s10230-010-0126-0. Acesso em: 27 mar 2025
Resumen en portugués brasileño: Resíduos de carvão pirítico produzidos por uma usina de beneficiamento de carvão no estado de Santa Catarina, no Sul O Brasil é gerador de ácido. Aqui relatamos a segunda parte de um estudo avaliando o uso de cobertura seca para minimizar geração de drenagem ácida de minas e seu lançamento no ambiente. Esta parte abrange a construção e monitoramento inicial de uma unidade experimental em escala piloto. Local argilas e cinzas de uma usina foram usadas como cobertura materiais. O monitoramento começou em outubro de 2007 e prorrogar por pelo menos 4 anos. Resultados iniciais da cobertura seca sistema construído com argila compactada localmente disponível e as cinzas parecem promissoras. O pH da drenagem variou de 6,0 a 7,0, dentro dos limites legais para lançamento em o ambiente.
Abstract: Pyritic coal wastes produced by a coal beneficiation plant in the state of Santa Catarina in Southern Brazil are acid generating. Here we report the second part of a study evaluating the use of a dry cover to minimize acid mine drainage generation and its release into the environment. This part encompasses the construction and initial monitoring of an experimental pilot-scale unit. Local clays and ash from a power station were used as cover materials. Monitoring started in October 2007 and will extend for at least 4 years. Initial results of the dry cover system constructed using compacted locally available clay and ash look promising. The pH of the drainage ranged from 6.0 to 7.0, within the legal limits for discharge into the environment.
URL del documento: https://link.springer.com/content/pdf/10.1007/s10230-010-0126-0.pdf
URI : http://repositorio.ufc.br/handle/riufc/80201
DOI: 10.1007/s10230-010-0126-0
ISSN : 1616-1068
ORCID del autor: 0000-0003-0708-3702
Lattes del autor: http://lattes.cnpq.br/8086699997411133
Derechos de acceso: Acesso Aberto
Aparece en las colecciones: DEHA - Artigos publicados em revista científica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
2010_art_absoares.pdf866,12 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.