Please use this identifier to cite or link to this item: http://repositorio.ufc.br/handle/riufc/69413
Type: Artigo de Periódico
Title: Proposta de nova configuração de reator anaeróbio híbrido aplicado ao tratamento de esgoto sanitário
Title in English: Proposal of a new configuration of hybrid anaerobic reactor applied to sanitary sewage treatment
Authors: Hoyos, Nestor Leonel Muñoz
Barroso Júnior, José Carlos Alves
Leal, Felipe Krüger
Barrantes, Eddie Francisco Gómez
Monteggia, Luiz Olinto
Keywords: Reator híbrido;Tratamento anaeróbio;Esgoto sanitário;Turbidez;Sólidos suspensos
Issue Date: 2019
Publisher: Revista DAE
Citation: BARROSO JÚNIOR, J. C. et al. Proposta de nova configuração de reator anaeróbio híbrido aplicado ao tratamento de esgoto sanitário. Revista DAE, [s.l], v. 67, n. 219, p. 73-88, out./dez. 2021. DOI: https://doi.org/10.4322/dae.2019.046
Abstract in Brazilian Portuguese: Este trabalho apresenta a avaliação do desempenho de uma nova configuração de reator anaeróbio híbrido (RAH) baseada no emprego de uma câmara de entrada de fluxo descendente seguida de uma câmara de fluxo ascendente. O RAH foi alimentado com esgoto sanitário e operado por um período de 240 dias com vazão afluente de 1,6 m3.h-1. Os resultados obtidos nessa fase experimental foram comparados com os obtidos em um reator UASB nas mesmas condições de clima e parâmetros operacionais. O reator híbrido apresentou estabilidade no processo de digestão anaeróbia e desempenho operacional eficiente, mostrando-se robusto para suportar choques de carga hidráulica e orgânica devido à variabilidade do esgoto típico da região sul do Brasil. A análise estatística dos resultados demostrou que o desempenho operacional dos reatores não apresentou diferença estatística significativa para remoção de DQO com valores de 66±15% e 62±17% e SST de 65±19% e 63±20%, para o RAH e o UASB respectivamente. A concentração de biomassa no RAH (3,7 kgSV.m-3) foi menor quando comparada ao reator UASB (12,4 kgSV.m-3); entretanto, esse fato não comprometeu a eficiência de remoção de matéria orgânica e de sólidos suspensos. Foi também demonstrada a viabilidade do uso da turbidez como parâmetro de controle operacional para a identificação de perda de lodo, mediante análise da relação SST e turbidez efluente.
Abstract: This work presents the performance evaluation of a new configuration of a hybrid anaerobic reactor (RAH) based on the use of a downflow inlet chamber followed by an upflow chamber. The RAH was operated for a period of 240 days with an influent flow rate of 1.6 m3.h-1 of sanitary sewage. The results obtained in this experimental phase were compared with those obtained in a UASB reactor under the same climatic conditions and operational parameters. The operating performance was acceptable, proving to be robust to withstand the organic shock loads due to the variability of the typical sewage from southern Brazil. The statistical analysis of the results showed that the operational performance of the reactors did not present significant statistical difference for COD removal with values 66±15% and 62±17% and 65±19% and 63±20% for SST, respectively for the RAH and the UASB. The biomass concentration in the RAH (3.7 kgSV. m-3) was lower when compared to the UASB reactor (12.4 kgSV. m-3), however, this fact did not compromise the efficiency of organic matter and suspended solids removal. It was also demonstrated the possibility of using turbidity as a parameter of operational control for the identification of sludge loss, based on the results of the SST to turbidity relation.
URI: http://www.repositorio.ufc.br/handle/riufc/69413
ISSN: 2675-4959
Access Rights: Acesso Aberto
Appears in Collections:DEHA - Artigos publicados em revista científica

Files in This Item:
File Description SizeFormat 
2019_art_jcabjunior.pdf730,5 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.