Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ufc.br/handle/riufc/58322
Tipo: Artigo de Periódico
Título : Aplicação do modelo Cormix para avaliar impacto ambiental na área costeira
Título en inglés: Application of the Cormix model to assess environmental impact in the coastal area: an example of the ocean disposal system for sanitary sewers in the city of Fortaleza (Ceará, Brazil)
Autor : Maia, Luis Parente
Bezerra, Maria Oziléia
Pinheiro, Lidriana de Souza
Redondo, José Manuel
Palabras clave : Meio ambiente;Água
Fecha de publicación : 2011
Editorial : Journal of Coastal Research
Citación : MAIA, Luis Parente, BEZERRA, Maria Oziléia; PINHEIRO, Lidriana de Sousa; REDONDO, José Manuel. Application of the Cormix model to assess environmental impact in the coastal area: an example of the ocean disposal system for sanitary sewers in the city of Fortaleza (Ceará, Brazil). Journal of Coastal Research, Polônia, v. 64, p. 922-926, 2011.
Abstract: Cornell Mixing Zone Expert System-CORMIX software was used to simulate the behavior of effluents discharged by the underwater emissary in Fortaleza (Ceará, Brazil). This software is used to analyze and predict the discharge design in bodies of water. Application of the CORMIX model was determined to simulate the tracer discharge using local environmental parameters and underwater emissary discharge data. Data on wind, current and position in relation to the coast were used in the chosen case to obtain the discharge flow classification from the model since the hydrodynamic dispersion fields are differentiated by the predominance of different physical processes responsible for the dispersion and mixture of effluents. The simulations carried out considering the characteristics of the underwater emissary, liquid effluents and receiving medium show a very high dilution capacity. The dilution is directly related to coastal current speed ranging between 1:45 and 1:278, respectively the minimum and maximum for the mixture’s initial zone dilution, with diffuser distances between16 and 55 meters. This gives the system the characteristic of good dilution capacity compared to other installed systems. At the limit of the simulations, 5.000 m from the diffuser, dilutions reached values between X1:251 and 1:2.688. From the simulations, it is possible to observe that given the difference in density between the effluent (freshwater) and the sea, the plume presents strong positive buoyancy. Thus, if we consider the unfavorable speeds and currents (0,25-direction and 0,04 - speed) we would have a P = 0,25 x 0,04 or P =0,01 (1%) probability of occurrence. However, for the actual situation, this probability is near zero. The results obtained from using the CORMIX model helped in the environmental monitoring of the effluent disposal area. Cornell Mixing Zone Expert System-CORMIX software was used to simulate the behavior of effluents discharged by the underwater emissary in Fortaleza (Ceará, Brazil). This software is used to analyze and predict the discharge design in bodies of water. Application of the CORMIX model was determined to simulate the tracer discharge using local environmental parameters and underwater emissary discharge data. Data on wind, current and position in relation to the coast were used in the chosen case to obtain the discharge flow classification from the model since the hydrodynamic dispersion fields are differentiated by the predominance of different physical processes responsible for the dispersion and mixture of effluents. The simulations carried out considering the characteristics of the underwater emissary, liquid effluents and receiving medium show a very high dilution capacity. The dilution is directly related to coastal current speed ranging between 1:45 and 1:278, respectively the minimum and maximum for the mixture’s initial zone dilution, with diffuser distances between16 and 55 meters. This gives the system the characteristic of good dilution capacity compared to other installed systems. At the limit of the simulations, 5.000 m from the diffuser, dilutions reached values between X1:251 and 1:2.688. From the simulations, it is possible to observe that given the difference in density between the effluent (freshwater) and the sea, the plume presents strong positive buoyancy. Thus, if we consider the unfavorable speeds and currents (0,25-direction and 0,04 - speed) we would have a P = 0,25 x 0,04 or P =0,01 (1%) probability of occurrence. However, for the actual situation, this probability is near zero. The results obtained from using the CORMIX model helped in the environmental monitoring of the effluent disposal area.
URI : http://www.repositorio.ufc.br/handle/riufc/58322
ISSN : 0749-0208
Aparece en las colecciones: LABOMAR - Artigos publicados em revistas científicas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
2011_art_lpmaia.pdf1,12 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.