Use este identificador para citar ou linkar para este item: http://repositorio.ufc.br/handle/riufc/78695
Tipo: Artigo de Periódico
Título: Energy harvesting influences electrochemical performance of microbial fuel cells
Autor(es): LOBO, Fernanda Leite
WANG, Xin
REN, Zhiyong Jason
Palavras-chave em português: Célula de combustível microbiana;Ponto de potência máximo;Colheita de energia;Águas Residuais
Palavras-chave em inglês: Microbial fuel cell;Maximum current point;Energy harvesting;Wastewater
CNPq: CNPQ::ENGENHARIAS::ENGENHARIA SANITARIA::SANEAMENTO AMBIENTAL::MICROBIOLOGIA APLICADA E ENGENHARIA SANITARIA
Data do documento: 2017
Instituição/Editor/Publicador: Journal of Power Sources
Citação: LOBO, Fernanda Leite; WANG, Xin ; REN, Zhiyong Jason. Energy harvesting influences electrochemical performance of microbial fuel cells. Jornal of Power Sources, [s.l.], v. 356, p. 356 - 364, 2017.
Resumo: As células de combustível microbianas (MFCs) podem ser fontes de energia eficazes para sensoriamento remoto, tratamento de águas residuais e remediação ambiental, mas seu desempenho precisa de melhorias significativas. Este sistema de estudo-analisa automaticamente como a colheita ativa usando circuitos elétricos aumentou os resultados do sistema MFC conforme em comparação com resistores passivos, não apenas no tradicional ponto de potência máxima (MPP), mas também em outros pontos operacionais desejados, como o ponto de corrente máxima (MCP) e o ponto de tensão máxima (MVP). Os resultados mostram que a colheita ativa no MPP aumentou a produção de energia em 81e375% e a colheita ativa a colheita em MCP aumentou a eficiência Coulombic em 207e805% em comparação com resistências operadas no mesmos pontos. Os voltamogramas cíclicos revelaram alterações no potencial redox e apoiaram o desempenho dados. As descobertas demonstram que a colheita ativa é uma abordagem muito eficaz para melhorar o MFC desempenho em diferentes pontos operacionais.
Abstract: Microbial fuel cells (MFCs) can be effective power sources for remote sensing, wastewater treatment and environmental remediation, but their performance needs significant improvement. This study system-atically analyzes how active harvesting using electrical circuits increased MFC system outputs as compared to passive resistors not only in the traditional maximal power point (MPP) but also in other desired operating points such as the maximum current point (MCP) and the maximum voltage point (MVP). Results show that active harvesting in MPP increased power output by 81e375% and active harvesting in MCP increased Coulombic efficiency by 207e805% compared with resisters operated at the same points. The cyclic voltammograms revealed redox potential shifts and supported the performance data. The findings demonstrate that active harvesting is a very effective approach to improve MFC performance across different operating points.
URL do documento: https://pdf.sciencedirectassets.com/271367/1-s2.0-S0378775317X00153/1-s2.0-S0378775317303658/main.pdf?X-Amz-Security-Token=IQoJb3JpZ2luX2VjECkaCXVzLWVhc3QtMSJHMEUCIDuYvBSLpncIo6yvk%2BCttiPAN85VvMDrYtrb4dnEgqIzAiEA8r6uh7wtGvgTOyfvJrnVanKMODoCJZdvhWxjq2NZ7%2BwquwUI8v%2F%2F%2F%2F%2F%2F%2F%2F%2F%2FARAFGgwwNTkwMDM1NDY4NjUiDE3uhF3Zi8jSmiRlFSqPBWcBukknxpa1fzDFIHV%2BdqU5u%2BUIge6zUnhpOcLMM4t9nbbXFkYTf8JZ0D8WioaH9L7zpeRx%2BiRm6FX32PwYdx1qTYPhG3mJvkbIacoYUVQ5zraqb3V7awKs8610b8jjJBTuLQq3OwDfFH3JwlvOUikiOiywDDCZ0lYnxXDeb3xOyIDucW%2BXEiIrK1SykTENHIV8Xh7de9XPiFsQKg71ykbYBabiy5pmoP5cUnBBOCG10sZcoDHw%2F%2FtiiJflqmjl6szSuIt07ELpOrr%2FiCZ7mOSvuhZevTzm4g1Lq4toPhW898bWAvf0we9Dlhqx4DIws%2F5mN%2F6%2FAVR1KuLM9eaFXQvqRdvselGDahYYc1Oaq%2BstZhP8z1zNIoYYllOl7rXlAMCShLAm3Wnz79wUa4CwbjQ35qZGV43WG11Hn6zxscAWv3yIG%2FSs2nldSyGDv9N%2BwRX%2B2Lqmyt1%2BGPm0CdPOq28qrW%2Fxh1%2F1yG3kK06gDbzJtGi7fAtU9vFHan%2Flh5L5jyUxo2bFCq%2BoQZz%2BpVdOGYOkSO6M6wUWTyfizGLXZwS1%2FweOuyNHYTmEhJRKrZ9zth97oujjG02Ek9Kx5ZcT8gfzdGqKfG74B3Ewk1y%2F6q5sFyRWRcnx0iYXh1KsvLGFoUEqQVBi8HNjsjz6bfHQNR%2FzDlmMVzCQ%2FjHPiaX8wVHIyLqs%2Bkmc2jhirxLaOrGimbEO1E6BRGqy3L1N7fSaBH2geNVz4tKocO7pGyhLyrs%2BshxTJWduayqMayUWEtnUxO62o0HILnshS05x26%2Fan2U2%2BzK4VtQn9fgHaBh%2BgudRBPKDcxHOysOgAXNyGd5MiK6IiowS2M6Za19ahytRGEeLZDlNXgbm59DInSvKBX0w3u%2FftAY6sQEkAjdrvcEZNgaSo0GxEbD11cIT3MU7zgyAAqabf4dVOtEy3MypsupYgibhXEnRkbGp265x16NEOw6cGnwpetOveD31Mr1v79MnAaF7%2BdVUeHtATIItakZLrLO4CeaAnNOpicOE0oyPN4G28qjpFegAEnC4ld%2BspBaDzRiW10RUgeGc79xnlwrH735Bxy3U6O4EZuqNTh2SOzLXfg%2BicO7zuy%2BAgKxN%2B7LYNAds%2FyXV5mY%3D&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Date=20240717T183723Z&X-Amz-SignedHeaders=host&X-Amz-Expires=300&X-Amz-Credential=ASIAQ3PHCVTYYUG7GQHG%2F20240717%2Fus-east-1%2Fs3%2Faws4_request&X-Amz-Signature=8eef4143dc7e2def32da2315c01b1054b249cfed46a1ecd864e270a51feb5115&hash=f94e4ccecc71064038e0819147a3d467195085e4b24a01663e2f648f716d3aa9&host=68042c943591013ac2b2430a89b270f6af2c76d8dfd086a07176afe7c76c2c61&pii=S0378775317303658&tid=spdf-ba935160-bfcd-415f-9717-99c4cf780ffa&sid=cdf743ce1877c049812aa875706d2510e774gxrqa&type=client&tsoh=d3d3LnNjaWVuY2VkaXJlY3QuY29t&ua=071d5c03520d565705&rr=8a4c57cf39f54f83&cc=br
URI: http://repositorio.ufc.br/handle/riufc/78695
Identificador DOI: http://dx.doi.org/10.1016/j.jpowsour.2017.03.067
ISSN: 0378-7753
ORCID do(s) Autor(es): 0000-0002-9468-7039
Currículo Lattes do(s) Autor(es): http://lattes.cnpq.br/2038180250879520
Tipo de Acesso: Acesso Aberto
Aparece nas coleções:DEHA - Artigos publicados em revista científica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2017_art_fllobo1.pdf3,11 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.