Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ufc.br/handle/riufc/68964
Tipo: Artigo de Periódico
Título : Multiresidue determination of endocrine disrupting compounds in sewage treatment plants (SPE-HPLC-DAD)
Autor : Vidal, Carla Bastos
Barbosa, Pablo Gordiano Alexandre
Pessoa, Germana de Paiva
Buarque, Patrícia Marques Carneiro
Nascimento, José Gilmar da Silva do
Farias Filho, Antônio Lima
Paz, Mário Sérgio de Oliveira
Santos, André Bezerra dos
Cavalcante, Rivelino Martins
Nascimento, Ronaldo Ferreira do
Palabras clave : Endocrine disruptors;Wastewater;High-Performance liquid chromatography;Reator UASB;Solid-Phase extraction;Disruptores endócrinos;Águas residuais;Cromatografia líquida de alta pressão;Extração em fase sólida
Fecha de publicación : 2020
Editorial : Journal of the Brazilian Chemical Society
Citación : SANTOS, A. B. et al. Multiresidue determination of endocrine disrupting compounds in sewage treatment plants (SPE-HPLC-DAD). Journal of the Brazilian Chemical Society, [s.l.], v. 31, n. 12, p. 2518-2530, 2020. DOI: https://dx.doi.org/10.21577/0103-5053.20200127
Abstract: This work focuses on the validation and application of solid phase extraction followed by high-performance liquid chromatography (SPE-HPLC) analysis of important endocrine disruptors compounds (EDC) from different classes in highly complex wastewater matrix. The endocrine disruptors investigated included three different categories: pharmaceuticals (sulfamethoxazole (SMZ), trimethoprim (TMP) and diclofenac (DCF)), hormones (estrone (E1), 17α-ethinylestradiol (EE2) and 17β-estradiol (E2)) and plastic materials (bisphenol A (BPA)). The method involves pre-concentration by SPE using Strata-X extraction cartridges followed by HPLC coupled with diode array detector (DAD). As the assumption of homoscedasticity was met for analytical data, ordinary linear regression procedure was applied to the data. The method was considered validated for 7 EDC after consistent evaluation of the key analytical parameters. Recoveries were ranged from 52.3 to 179.6%. Limits of quantification were in the range 6.0-0.4 µg L−1. The described method was applied to evaluate the occurrence and removal efficiency of EDC in two biological sewage treatment plants (STPs). The influent mean concentrations of E1, E2 and EE2 hormones were 79.54; 175.09 and 102.19 µg L−1, respectively, while for SMZ, TMP, DCF and BPA were 215.17; 187.01; 218.97 and 87.12 µg L−1 for STP A, respectively. The efficiencies for the removal of EDCs ranged from 0 to 79.4%.
URI : http://www.repositorio.ufc.br/handle/riufc/68964
ISSN : 1678-4790
Derechos de acceso: Acesso Aberto
Aparece en las colecciones: DEHA - Artigos publicados em revista científica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
2020_art_absantos.pdf1,69 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.