Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ufc.br/handle/riufc/67901
Tipo: Artigo de Periódico
Título : Novel and powerful 3D adaptive crisp active contour method applied in the segmentation of CT lung images
Autor : Rebouças Filho, Pedro Pedrosa
Cortez, Paulo César
Barros, Antonio Carlos da Silva
Albuquerque, Victor Hugo Costa de
Tavares, João Manuel Ribeiro da Silva
Palabras clave : CT scan;Image segmentation;3D reconstruction;Lung structures
Fecha de publicación : 2017
Editorial : Medical Image Analysis
Citación : CORTEZ, P. C. et al. Novel and powerful 3D adaptive crisp active contour method applied in the segmentation of CT lung images. Medical Image Analysis, vol. 35, p. 503-516, 2017. DOI: 10.1016/j.media.2016.09.002
Abstract: The World Health Organization estimates that 300 million people have asthma, 210 million people have Chronic Obstructive Pulmonary Disease (COPD), and, according to WHO, COPD will become the third major cause of death worldwide in 2030. Computational Vision systems are commonly used in pulmonology to address the task of image segmentation, which is essential for accurate medical diagnoses. Segmentation defines the regions of the lungs in CT images of the thorax that must be further analyzed by the system or by a specialist physician. This work proposes a novel and powerful technique named 3D Adaptive Crisp Active Contour Method (3D ACACM) for the segmentation of CT lung images. The method starts with a sphere within the lung to be segmented that is deformed by forces acting on it towards the lung borders. This process is performed iteratively in order to minimize an energy function associated with the 3D deformable model used. In the experimental assessment, the 3D ACACM is compared against three approaches commonly used in this field: the automatic 3D Region Growing, the level-set algorithm based on coherent propagation and the semi-automatic segmentation by an expert using the 3D OsiriX toolbox. When applied to 40 CT scans of the chest the 3D ACACM had an average F-measure of 99.22%, revealing its superiority and competency to segment lungs in CT images.
URI : http://www.repositorio.ufc.br/handle/riufc/67901
ISSN : 1361-8423
Aparece en las colecciones: DETE - Artigos publicados em revista científica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
2017_art_pccortez.pdf3,17 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.