Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ufc.br/handle/riufc/56537
Tipo: Artigo de Periódico
Título : Strategies for upgrading primary facultative ponds in Fortaleza, Northeast Brazil
Autor : Silva, Fernando José Araújo da
Souza, Raimundo Oliveira de
Castro, Francisco José Ferreira de
Palabras clave : Qualidade de efluente;Redesenho de sistemas de lagoas;Lagoa de estabilização
Fecha de publicación : 2009
Citación : SILVA, Fernando José Araújo da; SOUZA, Raimundo Oliveira de; CASTRO, Francisco José Ferreira de. Strategies for upgrading primary facultative ponds in Fortaleza, Northeast Brazil. Rev. Tecnol., Fortaleza, v.30, n.1, p. 104-113, jun. 2009.
Resumen en portugués brasileño: Durante as últimas duas décadas o emprego de lagoas de estabilização teve avanço considerável no Brasil. Ao mesmo tempo, a evolução desta tecnologia foi acompanhada por normas ambientais mais restritivas com respeito à qualidade dos efluentes. Assim, os sistemas de lagoas mais antigos, compostos essencialmente de lagoas facultativas primárias, não atendem às demandas normativas mais estritas. O presente estudo lida com alternativas de projeto para seis sistemas de lagoa localizados em Fortaleza (38o 32' O; 3o 43' S), Nordeste do Brasil. Para cada planta seis arranjos diferentes foram considerados com a inclusão de reatores anaeróbios e lagoas de maturação. Em três deles foi incluído um filtro de polimento. Nos sistemas sem filtro de polimento a remoção de DBO e DQO não filtradas alcançaria 84 e 79%, respectivamente. Com amostras filtradas o desempenho seria de 95 e 91%, respectivamente. Para os novos arranjos com filtro de polimento o desempenho seria de 92 e 90% de BOD e DQO, respectivamente. A remoção de coliformes fecais subiria em média de 1,362 logs nas lagoas de facultativas primárias para 3,916 logs nos novos arranjos propostos.
Abstract: During the last two decades waste stabilization ponds had a considerable advance in Brazil. In parallel, the evolution of this technology was accompanied by an increasing restrictive environmental regulation with regard to effluent standards. Thus, old plants comprised basically by single primary facultative ponds do not meet new stringent demands. The present paper deals with upgrading alternatives for six full-scale pond systems located at Fortaleza (38o 32' W; 3o 43' S), northeast Brazil. For each plant six different arrangements were considered with the inclusion of anaerobic reactors and maturation ponds. In three of them a polishing filter was considered. For those without a polishing filter the removal of unfiltered BOD and COD would reach 84 and 79%, respectively. For filtered samples the performance would increase to 95 and 91%, respectively. For the new arrangements with a polishing filter the performance would be 92 and 90% for BOD and COD, respectively. On average faecal coliform removal would rise from 1.362 logs in primary facultative ponds to 3.916 logs in the new plant schemes.
URI : http://www.repositorio.ufc.br/handle/riufc/56537
ISSN : 2318-0730
Derechos de acceso: Acesso Aberto
Aparece en las colecciones: DEHA - Artigos publicados em revista científica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
2009_art_fjasilva.pdf277,67 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.