Título : Avaliação metrológica de hidrômetros utilizados em perímetros irrigados do Brasil e Espanha
Título en inglés: Metrological evaluation of water meters used in irrigated perimeters in Brazil and Spain
Autor : Morais, Gislane Mendes de
Tutor: Azevedo, Benito Moreira de
Palabras clave : Hidrometria;Manejo de irrigação;Erro de medição;Hydrometry;Irrigation management;Measurement error
Fecha de publicación : 2019
Citación : MORAIS, Gislane Mendes de. Avaliação metrológica de hidrômetros utilizados em perímetros irrigados do Brasil e Espanha. 2019. 49 f. Tese (Doutorado em Engenharia Agrícola) – Universidade Federal do Ceará, Fortaleza, 2019.
Resumen en portugués brasileño: A posição de instalação é um dos fatores que podem afetar o desempenho metrológico de hidrômetros velocimétricos multijatos, pela possibilidade de reduzir a precisão e a vida útil dos equipamentos. Portanto, o objetivo deste trabalho foi avaliar os efeitos de três posições de instalação (horizontal, horizontal girado e vertical) sobre a curva de erro de hidrômetros velocimétricos multijatos utilizados em perímetros irrigados do Brasil e da Espanha. Foram selecionados para os ensaios oito hidrômetros de fabricação espanhola e dois hidrômetros de fabricação brasileira, com diferentes tempos de uso. Os ensaios de bancada foram conduzidos no Laboratório de Hidráulica y Riegos (LHIR) da Universitat Politècnica de València (UPV), Valência, Espanha, conforme as normas técnicas da Organização Internacional de Normalização (ISO 4064). Foram confeccionadas, nas três posições de instalação, duas curvas de erro para cada equipamento, a partir dos erros de medição estimados com vazões crescentes e decrescentes. O erro de medição foi calculado pela comparação entre o volume medido pelo hidrômetro e o volume de referência, obtido por meio de um tanque de pesagem. Foram considerados aceitáveis os erros de medição com limite máximo de ± 2% entre as vazões mínima e de transição, e de ± 5% entre as vazões de transição e a máxima. De acordo com os resultados, a posição horizontal foi a que menos afetou negativamente a precisão da maioria dos hidrômetros. As posições horizontal girado e, principalmente, vertical, provocaram na maioria dos hidrômetros erros de medição que ultrapassaram os limites recomendados pelas normas técnicas. Nessas posições, um dos hidrômetros com tempo de uso elevado não registrou o consumo de água em vazões elevadas. A conclusão do estudo é que a posição de instalação horizontal, comparada às posições horizontal girado e vertical, é a que proporciona os menores erros de medição e a que mais os mantem dentro dos limites aceitáveis. Ademais, essa posição de instalação pode reduzir o desgaste prematuro das peças móveis e, com isso, aumentar a durabilidade dos equipamentos. Vale ressaltar que a utilização de hidrômetros operando com precisão aceitável durante um período prolongado pode beneficiar consumidores, empresas de abastecimento e ambiente, pela redução de custos e preservação de recursos hídricos.
Abstract: The installation position of multi-jet velocimetric water meters is one of the factors that can interfere with its metrological performance, with the possibility of decreasing the sensitivity of its mobile mechanisms, and thus, under-measurement and over-measurement errors can occur. Thus, the present work aimed to study and evaluate the installation positioning of the flow measurement equipment, that is, to test through bench tests in the laboratory, the functioning of the hydrometers used in different installation positions: horizontal, horizontal rotated and vertical, and observe if the positioning can generate a difference in the final flow. The tests were carried out on water meters used in irrigated perimeters in the state of Ceará in comparison with those of communities in Spain. The tests carried out for the bench tests were conducted at the Hydraulic and Irrigation Laboratory of the Polytechnic University of Valencia (UPV), located in the city of Valencia, Spain. The laboratory has adequate structure and equipment to carry out the tests. It is part of the certification and standardization committee for irrigation material and hydraulic installations and has technical approval of European Union (UNE) standards. The test consisted of testing the hydrometers in three different positions (horizontal, horizontal, rotated and vertical) and checking if their operation was within the limits of error acceptable by the technical standards established by ISO 4064. The test procedure of the hydrometers was based on the circulation of water upstream and downstream of the hydrometer, causing the water to circulate throughout the pipeline, crossing the hydrometer and recording the volume on the meter clock until it flows into the weighing tank, for the receipt of water and registration of its mass. Reaching, with that, the data necessary to calculate the measurement error. The maximum tolerance of the acceptable measurement error is the error to be within the limits of ± 5% between the minimum flow (Qmin) and the transition flow (Qt), where these limits comprise the lower measurement field and ± 2% between the transition flow (Qt) and the maximum flow (Qmax), comprising the upper measurement field (ISO 4064). The metrology of the hydrometers, knowing the quality of the equipment, the conditions of installation and operation are of fundamental importance for a decision on water management in the agriculture sector. Thus, the most suitable and recommended installation position for a better performance of multi-jet velocimetric water meters was in the horizontal installation position, that is, with the turbine axis in the vertical position. Another factor observed in the operation of this equipment was its age, where it is related to its time of use. The time of use of the hydrometer can be observed through its accumulated volume and the hydrometers that presented a greater accumulated volume also had an influence on the proper functioning of its mechanisms.