Use este identificador para citar ou linkar para este item: http://repositorio.ufc.br/handle/riufc/50199
Tipo: Artigo de Periódico
Título: Penetration of bioceramic and epoxy-resin endodontic cements into lateral canals
Autor(es): Candeiro, George Táccio de Miranda
Lavor, Amanda Bezerra
Lima, Ilana Thaís de Freitas
Vasconcelos, Bruno Carvalho de
Gomes, Nilton Vivacqua
Elaine Faga Iglesias, Elaine Faga
Gavini, Giulio
Palavras-chave: Cavidade Pulpar;Dental Pulp Cavity;Obturação do Canal Radicular;Root Canal Obturation;Endodontia;Endodontics
Data do documento: Mai-2019
Instituição/Editor/Publicador: Brazilian Oral Research
Citação: CANDEIRO, George Táccio de Miranda et al. Penetration of bioceramic and epoxy-resin endodontic cements into lateral canals. Braz. oral res., São Paulo, v. 33, e049, may. 2019.
Abstract: The aim of the present study was to assess the penetration capacity of two endodontic cements, Endosequence BC Sealer and AH Plus, in artificial lateral canals. Twenty-six two-rooted, maxillary first premolars were instrumented to size 40.06 using K3 files. In each root, six lateral canals of two diameters (0.06 and 0.10 mm) were created with a working length of 2, 4, and 6 mm. The specimens were randomly divided into two groups according to the endodontic cement to be used (Endosequence BC Sealer and AH Plus) and obturated by the single-cone technique. The specimens were imaged by digital periapical radiography and scores from 0 to 4 were attributed according to the degree of penetration by sealers into the lateral canals. Data were analyzed statistically by Kruskal-Wallis and Student-Newman-Keuls tests, and a significance level of p < 0.05 was adopted. No significant difference was observed between the two endodontic cements used to fill the simulated lateral canals (p > 0.05). The diameter of lateral canals only influenced the capacity of the Endosequence BC Sealer in filling the canals, and presented greater penetration in the lateral canals of diameter 0.10 mm (p < 0.05). We concluded that the bioceramic endodontic cement Endosequence BC Sealer presented similar ability as AH Plus to fill simulated lateral canals.
URI: http://www.repositorio.ufc.br/handle/riufc/50199
ISSN: Print 1806-8324
On-line 1807-3107
Aparece nas coleções:DCOD - Artigos publicados em revistas científicas

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2019_art_gtmcandeiro.pdf200,96 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.