Use este identificador para citar ou linkar para este item: http://repositorio.ufc.br/handle/riufc/50199
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorCandeiro, George Táccio de Miranda-
dc.contributor.authorLavor, Amanda Bezerra-
dc.contributor.authorLima, Ilana Thaís de Freitas-
dc.contributor.authorVasconcelos, Bruno Carvalho de-
dc.contributor.authorGomes, Nilton Vivacqua-
dc.contributor.authorElaine Faga Iglesias, Elaine Faga-
dc.contributor.authorGavini, Giulio-
dc.date.accessioned2020-02-20T11:37:58Z-
dc.date.available2020-02-20T11:37:58Z-
dc.date.issued2019-05-
dc.identifier.citationCANDEIRO, George Táccio de Miranda et al. Penetration of bioceramic and epoxy-resin endodontic cements into lateral canals. Braz. oral res., São Paulo, v. 33, e049, may. 2019.pt_BR
dc.identifier.issnPrint 1806-8324-
dc.identifier.issnOn-line 1807-3107-
dc.identifier.urihttp://www.repositorio.ufc.br/handle/riufc/50199-
dc.description.abstractThe aim of the present study was to assess the penetration capacity of two endodontic cements, Endosequence BC Sealer and AH Plus, in artificial lateral canals. Twenty-six two-rooted, maxillary first premolars were instrumented to size 40.06 using K3 files. In each root, six lateral canals of two diameters (0.06 and 0.10 mm) were created with a working length of 2, 4, and 6 mm. The specimens were randomly divided into two groups according to the endodontic cement to be used (Endosequence BC Sealer and AH Plus) and obturated by the single-cone technique. The specimens were imaged by digital periapical radiography and scores from 0 to 4 were attributed according to the degree of penetration by sealers into the lateral canals. Data were analyzed statistically by Kruskal-Wallis and Student-Newman-Keuls tests, and a significance level of p < 0.05 was adopted. No significant difference was observed between the two endodontic cements used to fill the simulated lateral canals (p > 0.05). The diameter of lateral canals only influenced the capacity of the Endosequence BC Sealer in filling the canals, and presented greater penetration in the lateral canals of diameter 0.10 mm (p < 0.05). We concluded that the bioceramic endodontic cement Endosequence BC Sealer presented similar ability as AH Plus to fill simulated lateral canals.pt_BR
dc.language.isoenpt_BR
dc.publisherBrazilian Oral Researchpt_BR
dc.subjectCavidade Pulparpt_BR
dc.subjectDental Pulp Cavitypt_BR
dc.subjectObturação do Canal Radicularpt_BR
dc.subjectRoot Canal Obturationpt_BR
dc.subjectEndodontiapt_BR
dc.subjectEndodonticspt_BR
dc.titlePenetration of bioceramic and epoxy-resin endodontic cements into lateral canalspt_BR
dc.typeArtigo de Periódicopt_BR
Aparece nas coleções:DCOD - Artigos publicados em revistas científicas

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2019_art_gtmcandeiro.pdf200,96 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.