Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.ufc.br/handle/riufc/40714
Tipo: | Artigo de Periódico |
Título : | Interval robust controller to minimize oscillations effects caused by constant power load in a DC multi-converter Buck-Buck system |
Autor : | Marcillo, Kevin Eduardo Lucas Guingla, Douglas Antonio Plaza Medeiros, Renan Landau Paiva de Beavides, David Alejandro Vaca Nogueira, Fabrício Gonzalez |
Palabras clave : | Engenharia elétrica;Correntes elétricas;Conversores de frequência;Robust control based on Kharitonov rectangle;Mitigation oscillations in multi-converter buck-buck system;Constant power load;Multi-converter buck-buck system;Parametric uncertainties |
Fecha de publicación : | 2019 |
Editorial : | IEEE Access |
Citación : | MARCILLO, K. E. L. et al. Interval robust controller to minimize oscillations effects caused by constant power load in a DC multi-converter Buck-Buck system. IEEE Access, v. 7, p. 26324 - 26342, 2019. |
Abstract: | Multi-converter electronic systems are becoming widely used in many industrial applications; therefore, the stability of the whole system is a big concern to the real-world power supplies applications. A multi-converter system comprised of cascaded converters has a basic con guration that consists of two or more converters in series connection, where the rst is a source converter that maintains a regulated dc voltage on the intermediate bus while remaining are load converters that convert the intermediate bus voltage to the tightly regulated outputs for the next system stage or load. Instability in cascaded systems may occur due to the constant power load (CPL), which is a behavior of the tightly regulated converters. CPLs exhibit incremental negative resistance behavior causing a high risk of instability in interconnected converters. In addition, there are other problems apart from the CPL, e.g., non-linearities due to the inductive element and uncertainties due to the imprecision of a mathematical model of dc dc converters. Aiming to effectively mitigate oscillations effects in the output of source converter loaded with a CPL, in this paper, an interval robust controller, by linear programming based on Kharitonov rectangle, is proposed to regulate the output of source converter. Several tests were developed by using an experimental plant and simulation models when the multi-converter buck buck system is subjected to a variation of power reference. Both simulation and experimental results show the effectiveness of the proposed controller. Furthermore, the performance indices computed from the experimental data show that the proposed controller outperforms a classical control technique. |
URI : | http://www.repositorio.ufc.br/handle/riufc/40714 |
ISSN : | 2169 - 3536 |
Derechos de acceso: | Acesso Aberto |
Aparece en las colecciones: | DEEL - Artigos publicados em revista científica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
2019_art_fgnogueira.pdf | 2,99 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.