Please use this identifier to cite or link to this item:
http://repositorio.ufc.br/handle/riufc/28926
Type: | Artigo de Periódico |
Title: | Determination of the accuracy of 5 electronic apex locators in the function of different employment protocols |
Authors: | Oliveira, Tiago Nepomuceno Gomes, Nilton Vivacqua- Bernardes, Ricardo Affonso Vivan, Rodrigo Ricci Duarte, Marco Antonio Hungaro Vasconcelos, Bruno Carvalho |
Keywords: | Dental Pulp Cavity;Cavidade Pulpar |
Issue Date: | 2017 |
Publisher: | Journal of Endodontics |
Citation: | OLIVEIRA, T. N. et al. Determination of the accuracy of 5 electronic apex locators in the function of different employment protocols, Journal of Endodontics, Baltimore, v. 4, n. 10, p. 1663-1667, oct. 2017, |
Abstract in Brazilian Portuguese: | Introduction: The aim of this study was to evaluate the accuracy of 5 electronic apex locators (EALs): Root ZX II (RZX; J Morita, Tokyo, Japan), Raypex 6 (RAY; VDW GmbH, Munich, Germany), Apex ID (AID; SybronEndo, Orange, CA), Propex II (PRO; Dentsply Maillefer, Ballaigues, Switzerland), and Propex Pixi (PIXI, Dentsply Maillefer) when used in the following protocols: (1) 1.0, insertion up to 1.0 mm below the apical foramen (AF); (2) 0.0/ 1.0, insertion until the AF and withdrawn 1.0 mm short of the AF; (3) 0.0, insertion until the AF; and (4) over/0.0, insertion until ‘‘over’’ and withdrawal to AF. Methods: Thirty human lower premolars had coronary accesses and cervical and middle thirds preparations performed, allowing AF standardization (200 mm). Using an alginate experimental model, root canal length (RCL) measurements were performed sequentially with EALs following each of the protocols. Results: Considering the suggested protocols, the lowest mean error values were observed in 0.0, 0.10 mm (RZX), 0.13 mm (RAY), 0.16 mm (AID), 0.23 mm (PRO), and 0.10 mm (PIXI), without a significant difference for over/0.0 (P > .05). Comparing the results obtained in 0.0 with those found in 1.0 and 0.0/ 1.0, significant differences were observed for most EALs (P < .05). For the comparison between EALs, significant differences were observed only in protocols 1.0 and over/0.0 (P < .05). Conclusions: Under the conditions of the study, it was concluded that, regardless of the mechanism of the device, the best results were found when electronic RCL measurement was performed at the AF; furthermore, the electronic withdrawal did not offer any additional advantage over the reach of the AF. (J Endod 2017;43:1663–1667) |
URI: | http://www.repositorio.ufc.br/handle/riufc/28926 |
ISSN: | 0099-2399 |
Appears in Collections: | DCOD - Artigos publicados em revistas científicas |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2017_art_tnoliveira.pdf | 150,5 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.