Use este identificador para citar ou linkar para este item: http://repositorio.ufc.br/handle/riufc/73297
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorSampaio, Felipe Carvalho-
dc.contributor.authorTofoli, Fernando Lessa-
dc.contributor.authorMelo, Lucas Silveira-
dc.contributor.authorBarroso, Giovanni Cordeiro-
dc.contributor.authorSampaio, Raimundo Furtado-
dc.contributor.authorLeão, Ruth Pastôra Saraiva-
dc.date.accessioned2023-07-03T16:00:38Z-
dc.date.available2023-07-03T16:00:38Z-
dc.date.issued2023-
dc.identifier.citationSAMPAIO, Felipe Carvalho; TOFOLI, Fernando Lessa; MELO, Lucas Silveira; BARROSO, Giovanni Cordeiro; SAMPAIO, Raimundo Furtado; LEÃO, Ruth Pastôra Saraiva. Smart protection system for microgrids with grid-connected and islanded capabilities based on an adaptive algorithm. Energies, [S.L.], v. 16, p. 2273, 2023.pt_BR
dc.identifier.issn1996-1073-
dc.identifier.otherhttps://doi.org/10.3390/en16052273-
dc.identifier.urihttp://www.repositorio.ufc.br/handle/riufc/73297-
dc.description.abstractThis work proposes a smart protection system for microgrids, which relies on an adaptive metaheuristic for the automatic calculation of optimal settings for directional overcurrent relays (DOCRs). The adaptive fuzzy directional bat algorithm (AFDBA) associated with a fuzzy inference system (FIS) is used for this purpose. A prominent advantage of this solution is that there is no need for an initial tuning of the parameters associated with the algorithm, unlike many traditional approaches reported in the literature. Such a metaheuristic is used in the conception of an adaptive protection system (APS) in the context of a microgrid while taking into account the connection status of distributed generation (DG) units under distinct scenarios. A performance comparison with a protection system with fixed optimal settings (PSFOS) is also presented. The results demonstrate that the proposed APS outperforms the PSFOS while providing faster response, higher reliability and less susceptibility to miscoordination. In other words, it presents a shorter trip time when compared with he PSFOS, with a reduction of 6.83% and 26.58% when considering the DG penetration and the islanded microgrid, respectivelypt_BR
dc.language.isoenpt_BR
dc.publisherEnergiespt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectAdaptive protection systemspt_BR
dc.subjectDirectional overcurrent relayspt_BR
dc.subjectDistributed generationpt_BR
dc.subjectMetaheuristicspt_BR
dc.subjectMicrogridspt_BR
dc.subjectSistemas de proteção adaptáveispt_BR
dc.subjectRelés de sobrecorrente direcionaispt_BR
dc.subjectGeração distribuídapt_BR
dc.subjectMetaheurísticaspt_BR
dc.subjectMicrorredespt_BR
dc.titleSmart protection system for microgrids with grid-connected and islanded capabilities based on an adaptive algorithmpt_BR
dc.typeArtigo de Periódicopt_BR
Aparece nas coleções:DEEL - Artigos publicados em revista científica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2023_art_fcsampaio.pdf1,3 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.