Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.ufc.br/handle/riufc/69386
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Lopes, Amanda Fonsêca | - |
dc.contributor.author | Gouveia Júnior, Florêncio Sousa | - |
dc.contributor.author | Nascimento, Hélio Oliveira do | - |
dc.contributor.author | Silva, Vitor Paulo Andrade da | - |
dc.contributor.author | Barbosa, Pablo Gordiano Alexandre | - |
dc.contributor.author | Carvalho, Tecia Vieira | - |
dc.contributor.author | Nascimento, Ronaldo Ferreira do | - |
dc.date.accessioned | 2022-11-22T17:34:27Z | - |
dc.date.available | 2022-11-22T17:34:27Z | - |
dc.date.issued | 2022 | - |
dc.identifier.citation | NASCIMENTO, R. F. et al. A physical study to explain response differences between the BID and FID detectors for PAHs and pesticides. Journal of the Brazilian Chemical Society, [s.l.], v. 33, n. 10, p. 1190-1199, 2022. DOI: https://dx.doi.org/10.21577/0103-5053.20220038 | pt_BR |
dc.identifier.issn | 0103-5053 | - |
dc.identifier.uri | http://www.repositorio.ufc.br/handle/riufc/69386 | - |
dc.description.abstract | The dielectric barrier discharge ionization detector (BID) is one of the most modern detectors commercially available for gas chromatography (GC). Its technology based on the sample ionization through the energy released from the helium plasma generation process gives it the ability to act as a universal detector and a greater response to various types of compounds compared to the well-established flame ionization detector (FID). In this study, polycyclic aromatic hydrocarbons (PAHs), organophosphates (OPPs) and organochlorines pesticides (OCPs) were investigated. The parameters that could explain the performance of the BID and FID detectors were: structural factors, ionization energy (IE) and energy of the highest occupied molecular orbital (EHOMO), which were obtained by density functional theory (DFT). The relative (BID/FID) responses to PAHs and pesticides were about 1.8 and 3.0 times greater than FID, respectively. Less structural dependence of the BID signal compared to the FID signal was observed. Among the parameters calculated by DFT, the IE was the one that most seemed to have influenced the response of the two detectors studied. The theoretical data proved to be quite consistent to explain the trends observed experimentally, especially to the BID. | pt_BR |
dc.language.iso | en | pt_BR |
dc.publisher | Journal of the Brazilian Chemical Society | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.subject | Gas chromatography | pt_BR |
dc.subject | Dielectric barrier discharge ionization detector | pt_BR |
dc.subject | Flame ionization detector | pt_BR |
dc.subject | Density functional theory | pt_BR |
dc.subject | Ionization energy | pt_BR |
dc.title | A physical study to explain response differences between the BID and FID detectors for PAHs and pesticides | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
Aparece en las colecciones: | DEHA - Artigos publicados em revista científica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
2022_art_rfnascimento.pdf | 1,41 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.