Please use this identifier to cite or link to this item: http://repositorio.ufc.br/handle/riufc/67211
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAraújo, Josegil Jorge Pereira de-
dc.contributor.authorSantos, Carlos Antônio Cabral dos-
dc.contributor.authorHolanda, Carlos Almir Monteiro de-
dc.contributor.authorDuarte, João Batista Furlan-
dc.contributor.authorOchoa, Alvaro Antonio Villa-
dc.contributor.authorDutra, José Carlos Charamba-
dc.date.accessioned2022-07-18T18:55:15Z-
dc.date.available2022-07-18T18:55:15Z-
dc.date.issued2017-
dc.identifier.citationHOLANDA, C. A. et al. Energetic analysis of a commercial absorption refrigeration unit using an ammonia-water mixture. Acta Scientiarum. Technology, vol. 39, n. 4, p. 439-448, 2017pt_BR
dc.identifier.issn1807-8664-
dc.identifier.urihttp://www.repositorio.ufc.br/handle/riufc/67211-
dc.description.abstractThe ROBUR® absorption refrigeration system (ARS), model ACF60, with a capacity of 17.5 kW, is tested, modeled and simulated in the steady state. To simulate the thermal load a heating system with secondary coolant was used, in which a programmable logic controller (PLC) kept the inlet temperature EVA at around 285.15 K. The mathematical model used was based on balancing the mass, energy and ammonia concentrations and completed by closing equations such as, Newton's cooling equation. The mathematical model was implemented using the Engineering Equation Solver – EES®. The results obtained after modeling and a numerical permanent simulation are studied using the Duhring diagram. Potential points of internal heat recovery are visualized, and by using graphs of the binary mixture, it is possible to identify the thermodynamic states of all monitored points. The data obtained in the numerical simulation of the ARS was compared with data acquired in the actual tests of the ARS with the ROBUR® apparatus.pt_BR
dc.language.isoenpt_BR
dc.publisherActa Scientiarum. Technologypt_BR
dc.subjectAr condicionadopt_BR
dc.subjectSistema de absorçãopt_BR
dc.subjectSimulaçãopt_BR
dc.subjectResultados experimentaispt_BR
dc.subjectCOPpt_BR
dc.titleEnergetic analysis of a commercial absorption refrigeration unit using an ammonia-water mixturept_BR
dc.typeArtigo de Periódicopt_BR
Appears in Collections:DEMM - Artigos publicados em revista científica

Files in This Item:
File Description SizeFormat 
2017_art_caholanda.pdf1,05 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.