Please use this identifier to cite or link to this item:
http://repositorio.ufc.br/handle/riufc/67211
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Araújo, Josegil Jorge Pereira de | - |
dc.contributor.author | Santos, Carlos Antônio Cabral dos | - |
dc.contributor.author | Holanda, Carlos Almir Monteiro de | - |
dc.contributor.author | Duarte, João Batista Furlan | - |
dc.contributor.author | Ochoa, Alvaro Antonio Villa | - |
dc.contributor.author | Dutra, José Carlos Charamba | - |
dc.date.accessioned | 2022-07-18T18:55:15Z | - |
dc.date.available | 2022-07-18T18:55:15Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | HOLANDA, C. A. et al. Energetic analysis of a commercial absorption refrigeration unit using an ammonia-water mixture. Acta Scientiarum. Technology, vol. 39, n. 4, p. 439-448, 2017 | pt_BR |
dc.identifier.issn | 1807-8664 | - |
dc.identifier.uri | http://www.repositorio.ufc.br/handle/riufc/67211 | - |
dc.description.abstract | The ROBUR® absorption refrigeration system (ARS), model ACF60, with a capacity of 17.5 kW, is tested, modeled and simulated in the steady state. To simulate the thermal load a heating system with secondary coolant was used, in which a programmable logic controller (PLC) kept the inlet temperature EVA at around 285.15 K. The mathematical model used was based on balancing the mass, energy and ammonia concentrations and completed by closing equations such as, Newton's cooling equation. The mathematical model was implemented using the Engineering Equation Solver – EES®. The results obtained after modeling and a numerical permanent simulation are studied using the Duhring diagram. Potential points of internal heat recovery are visualized, and by using graphs of the binary mixture, it is possible to identify the thermodynamic states of all monitored points. The data obtained in the numerical simulation of the ARS was compared with data acquired in the actual tests of the ARS with the ROBUR® apparatus. | pt_BR |
dc.language.iso | en | pt_BR |
dc.publisher | Acta Scientiarum. Technology | pt_BR |
dc.subject | Ar condicionado | pt_BR |
dc.subject | Sistema de absorção | pt_BR |
dc.subject | Simulação | pt_BR |
dc.subject | Resultados experimentais | pt_BR |
dc.subject | COP | pt_BR |
dc.title | Energetic analysis of a commercial absorption refrigeration unit using an ammonia-water mixture | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
Appears in Collections: | DEMM - Artigos publicados em revista científica |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2017_art_caholanda.pdf | 1,05 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.