Use este identificador para citar ou linkar para este item: http://repositorio.ufc.br/handle/riufc/65105
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorSantos, Ângelo Marcílio Marques dos-
dc.contributor.authorPacífico, Ricardo Parcelle Cardoso-
dc.contributor.authorSilva, Leonardo Pires de Sousa-
dc.contributor.authorFrança, Marcos Vinícius Soares de-
dc.contributor.authorTeixeira, Vanessa Siqueira de Castro-
dc.contributor.authorMoreira, Adson Bezerra-
dc.date.accessioned2022-04-18T13:32:10Z-
dc.date.available2022-04-18T13:32:10Z-
dc.date.issued2020-
dc.identifier.citationSANTOS, Ângelo Marcílio Marques dos; PACÍFICO, Ricardo Parcelle Cardoso; SILVA, Leonardo Pires de Sousa; FRANÇA, Marcos Vinícius Soares de; TEIXEIRA, Vanessa Siqueira de Castro; MOREIRA, Adson Bezerra. Power control for a wind power Generation from SCIG and harmonic current filtering. In: CONGRESSO BRASILEIRO DE AUTOMÁTICA, XXIII., 23 e 26 de Novembro de 2020, Online. Anais[…], Campinas, Galoá, v. 2 , n. 1, 2020. CBA2020. DOI: 10.48011/asba.v2i1.1051pt_BR
dc.identifier.issn2525-8311-
dc.identifier.issnDOI: https://doi.org/10.48011/asba.v2i1.1051-
dc.identifier.urihttp://www.repositorio.ufc.br/handle/riufc/65105-
dc.description.abstractThe main contribution of this paper is to present a proposal for the development of an active power filter (APF) for a wind power generation system connected to the electric grid, using the three-phase induction generator with squirrel cage rotor (SCIG). In the induction generator side converter (IGSC) the power control is done by the magnetizing current and electromagnetic torque in coordinates dq. Thus, the wind system controls the active and reactive powers, as well as performing the active filtering function in the grid currents. Harmonic compensation is performed by an algorithm applied to the grid side converter (GSC). That technique improves the power quality and keeps the voltage at DC bus. The studied system was mathematically modeled and simulated using the Matlab / Simulink software. When SCIG provides 2 kW of active power, the THD from 18,94% (without APF) was reduced to 3,93% for GSC operating with APF function.pt_BR
dc.language.isopt_BRpt_BR
dc.publisherSociedade Brasileira de Automática (SBA) - https://www.sba.org.br/; Galoá Science - https://galoa.com.br/ - https://cba2020.galoa.com.br/pt_BR
dc.subjectElectric power generationpt_BR
dc.subjectElectronic back-to-back converterpt_BR
dc.subjectSCIGpt_BR
dc.subjectWind energypt_BR
dc.subjectActive power filterpt_BR
dc.subjectTHDpt_BR
dc.titlePower Control for a Wind Power Generation from SCIG and Harmonic Current Filteringpt_BR
dc.typeArtigo de Eventopt_BR
dc.title.enPower Control for a Wind Power Generation from SCIG and Harmonic Current Filteringpt_BR
Aparece nas coleções:DEEL - Trabalhos apresentados em eventos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2020_eve_ammdossantos.pdf1,83 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.