Use este identificador para citar ou linkar para este item:
http://repositorio.ufc.br/handle/riufc/62176
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Lima, Leonardo Coelho Rabello | - |
dc.contributor.author | Oliveira, Felipe Bruno Dias | - |
dc.contributor.author | Oliveira, Thiago Pires | - |
dc.contributor.author | Assumpção, Claudio de Oliveira | - |
dc.contributor.author | Greco, Camila Coelho | - |
dc.contributor.author | Cardozo, Adalgiso Croscato | - |
dc.contributor.author | Denadai, Benedito Sérgio | - |
dc.date.accessioned | 2021-11-18T13:05:05Z | - |
dc.date.available | 2021-11-18T13:05:05Z | - |
dc.date.issued | 2014 | - |
dc.identifier.citation | LIMA, Leonardo Coelho Rabello et al. Postactivation Potentiation Biases Maximal Isometric Strength Assessment. BioMed Research Internationa, [s. l.], v. 2014 , n. 4, p. 7, 2014. | pt_BR |
dc.identifier.uri | http://www.repositorio.ufc.br/handle/riufc/62176 | - |
dc.description.abstract | Postactivation potentiation (PAP) is known to enhance force production. Maximal isometric strength assessment protocols usually consist of two or more maximal voluntary isometric contractions (MVCs). The objective of this study was to determine if PAP would influence isometric strength assessment. Healthy male volunteers (n = 23) performed two five-second MVCs separated by a 180-seconds interval. Changes in isometric peak torque (IPT), time to achieve it (tPTI), contractile impulse (CI), root mean square of the electromyographic signal during PTI (RMS), and rate of torque development (RTD), in different intervals, were measured. Significant increases in IPT (240.6 ± 55.7 N⋅m versus 248.9 ± 55.1 N⋅m), RTD (746 ± 152 N⋅m⋅s−1 versus 727 ± 158 N⋅m⋅s −1), and RMS (59.1 ± 12.2% RMSMAX versus 54.8 ± 9.4% RMSMAX) were found on the second MVC. tPTI decreased significantly on the second MVC (2373 ± 1200 ms versus 2784 ± 1226 ms). We conclude that a first MVC leads to PAP that elicits significant enhancements in strength-related variables of a second MVC performed 180 seconds later. If disconsidered, this phenomenon might bias maximal isometric strength assessment, overestimating some of these variables. | pt_BR |
dc.language.iso | pt_BR | pt_BR |
dc.publisher | BioMed Research Internationa | pt_BR |
dc.title | Postactivation Potentiation Biases Maximal Isometric Strength Assessment | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
Aparece nas coleções: | IEFES - Artigos publicados em revistas científicas |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
2014_art_lcrlima.pdf | 210,66 kB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.