Use este identificador para citar ou linkar para este item: http://repositorio.ufc.br/handle/riufc/59758
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorHonorato, Renêe de Caldas-
dc.contributor.authorFerraz, Alex Soares Marreiros-
dc.contributor.authorKassiano, Witalo-
dc.contributor.authorCarvalho, Denise Pires-
dc.contributor.authorCeccatto, Vânia Marilande-
dc.date.accessioned2021-07-28T13:55:01Z-
dc.date.available2021-07-28T13:55:01Z-
dc.date.issued2021-
dc.identifier.citationHONORATO, Renêe de Caldas et al. Test-retest reliability of electrical impedance myography in hamstrings of healthy young men, Journal of Electromyography & Kinesiology, [s. l.], v. 56, p.1-5, 2021pt_BR
dc.identifier.urihttp://www.repositorio.ufc.br/handle/riufc/59758-
dc.description.abstractSeveral techniques are available to assess muscle tissue status, including electrical impedance myography (EIM). Despite being used in the assessment of neuromuscular status in injury and response to exercise, reliability data for hamstrings muscles are limited. Therefore, this study aimed to determine the test-retest reliability of EIM components on hamstrings. Twenty-one healthy males (25.3 ±3.4 years; 173 ±6.7 cm; and 79.7 ±15.9 kg) volunteered for this study. Subjects completed two visits, separated by seven days to collect EIM components (resistance, reactance, impedance, and phase angle) in the longitudinal and transversal axis of hamstrings in both thighs, using a bioimpedance device and Ag/AgCL adhesive contact electrodes. The electrode arrangement was in the muscular belly, half the distance between origin and insertion of the hamstrings. Reliability was deter-mined by the intraclass correlation coefficient (ICC), minimal detectable change (MDC), and Bland-Altman plots. We observed high to excellent reliability (ICC >0.85) between all EIM components, except for reactance with MDC ranged from 2.0 to 10.8 and the mean bias in Bland-Altman plots ranged frompt_BR
dc.language.isoenpt_BR
dc.publisherJournal of Electromyography & Kinesiologypt_BR
dc.subjectBioelectrical impedance spectroscopypt_BR
dc.subjectPosterior thighpt_BR
dc.subjectPhase anglept_BR
dc.subjectResistancept_BR
dc.subjectMusclept_BR
dc.titleTest-retest reliability of electrical impedance myography in hamstrings of healthy young menpt_BR
dc.typeArtigo de Periódicopt_BR