Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.ufc.br/handle/riufc/28926
Tipo: | Artigo de Periódico |
Título : | Determination of the accuracy of 5 electronic apex locators in the function of different employment protocols |
Autor : | Oliveira, Tiago Nepomuceno Gomes, Nilton Vivacqua- Bernardes, Ricardo Affonso Vivan, Rodrigo Ricci Duarte, Marco Antonio Hungaro Vasconcelos, Bruno Carvalho |
Palabras clave : | Dental Pulp Cavity;Cavidade Pulpar |
Fecha de publicación : | 2017 |
Editorial : | Journal of Endodontics |
Citación : | OLIVEIRA, T. N. et al. Determination of the accuracy of 5 electronic apex locators in the function of different employment protocols, Journal of Endodontics, Baltimore, v. 4, n. 10, p. 1663-1667, oct. 2017, |
Resumen en portugués brasileño: | Introduction: The aim of this study was to evaluate the accuracy of 5 electronic apex locators (EALs): Root ZX II (RZX; J Morita, Tokyo, Japan), Raypex 6 (RAY; VDW GmbH, Munich, Germany), Apex ID (AID; SybronEndo, Orange, CA), Propex II (PRO; Dentsply Maillefer, Ballaigues, Switzerland), and Propex Pixi (PIXI, Dentsply Maillefer) when used in the following protocols: (1) 1.0, insertion up to 1.0 mm below the apical foramen (AF); (2) 0.0/ 1.0, insertion until the AF and withdrawn 1.0 mm short of the AF; (3) 0.0, insertion until the AF; and (4) over/0.0, insertion until ‘‘over’’ and withdrawal to AF. Methods: Thirty human lower premolars had coronary accesses and cervical and middle thirds preparations performed, allowing AF standardization (200 mm). Using an alginate experimental model, root canal length (RCL) measurements were performed sequentially with EALs following each of the protocols. Results: Considering the suggested protocols, the lowest mean error values were observed in 0.0, 0.10 mm (RZX), 0.13 mm (RAY), 0.16 mm (AID), 0.23 mm (PRO), and 0.10 mm (PIXI), without a significant difference for over/0.0 (P > .05). Comparing the results obtained in 0.0 with those found in 1.0 and 0.0/ 1.0, significant differences were observed for most EALs (P < .05). For the comparison between EALs, significant differences were observed only in protocols 1.0 and over/0.0 (P < .05). Conclusions: Under the conditions of the study, it was concluded that, regardless of the mechanism of the device, the best results were found when electronic RCL measurement was performed at the AF; furthermore, the electronic withdrawal did not offer any additional advantage over the reach of the AF. (J Endod 2017;43:1663–1667) |
URI : | http://www.repositorio.ufc.br/handle/riufc/28926 |
ISSN : | 0099-2399 |
Aparece en las colecciones: | DCOD - Artigos publicados em revistas científicas |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
2017_art_tnoliveira.pdf | 150,5 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.