Use este identificador para citar ou linkar para este item: http://repositorio.ufc.br/handle/riufc/72973
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorBehzadipour, Arsalan-
dc.contributor.authorAzimi, Amir Hossein-
dc.contributor.authorLima Neto, Iran Eduardo-
dc.date.accessioned2023-06-21T18:21:51Z-
dc.date.available2023-06-21T18:21:51Z-
dc.date.issued2022-
dc.identifier.citationBEHZADIPOUR, Arsalan; AZIMI, Amir Hossein; LIMA NETO, Iran Eduardo. Effect of grid-screen on bubble characteristics of vertically discharged bubble plumes. Chemical Engineering Science, [S. l.], v. 253, n. 117545, p. 1-17, 2022.pt_BR
dc.identifier.issn0009-2509-
dc.identifier.urihttp://www.repositorio.ufc.br/handle/riufc/72973-
dc.description.abstractA series of laboratory experiments was conducted to improve the entrainment and mixing capacity of vertically discharged bubble plumes by employing a grid-screed with different openings and at different distances from the nozzle. Bubble characteristics such as bubble size, bubble size distribution, bubble concentration, and bubble velocity were measured using an accurate Refractive Bubble Index (RBI) probe along the plume, before, and after the grid-screen. The effects of grid-screen openings and airflow discharge on variations of bubble characteristics were examined. Experimental results showed that the size of grid-screen and its distance from the nozzle decreased the vertical velocity of bubbles by an average of 38%. Dynamics of bubbles before and after the grid-screen was analyzed and a regime classification was proposed based on variations of the normalized bubble velocity with the distance from the nozzle. It was found that increasing the distance between the grid-screen and nozzle increased bubble concentration by approximately 9% and reduced bubble size by 31%. At a certain distance from the nozzle, the effect of the grid-screen became negligible and bubble velocity reached its initial value. This specific distance was extracted for all tests and the results showed that such critical distance was correlated with the nozzle Reynolds number. Empirical correlations were developed to estimate the effective mixing length after the grid-screen. The proposed equations were found to be correlated with the bubble Reynolds number.pt_BR
dc.language.isoenpt_BR
dc.publisherChemical Engineering Sciencept_BR
dc.rightsAcesso Abertopt_BR
dc.subjectBubble plumept_BR
dc.subjectAir–water mixingpt_BR
dc.subjectBubble dynamicspt_BR
dc.subjectBubble sizept_BR
dc.subjectBubble velocitypt_BR
dc.subjectBubble breakuppt_BR
dc.subjectCoalescencept_BR
dc.titleEffect of grid-screen on bubble characteristics of vertically discharged bubble plumespt_BR
dc.typeArtigo de Periódicopt_BR
Aparece nas coleções:DEHA - Artigos publicados em revista científica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2022_art_abehzadipour1.pdf4,02 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.