Use este identificador para citar ou linkar para este item:
http://repositorio.ufc.br/handle/riufc/72197
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Oliveira, Sâmeque do Nascimento | - |
dc.contributor.author | Ribeiro, Francisco Wirley Paulino | - |
dc.contributor.author | Sousa, Camila Pinheiro | - |
dc.contributor.author | Lima, Janete Eliza Soares de | - |
dc.contributor.author | Suffredini, Hugo Barbosa | - |
dc.contributor.author | Becker, Helena | - |
dc.contributor.author | Lima Neto, Pedro de | - |
dc.contributor.author | Correia, Adriana Nunes | - |
dc.date.accessioned | 2023-05-11T17:32:13Z | - |
dc.date.available | 2023-05-11T17:32:13Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | OLIVEIRA, Sâmeque do Nascimento; RIBEIRO, Francisco Wirley Paulino; SOUSA, Camila Pinheiro; SUFFREDINE, Hugo Barbosa; BECKER, Helena; LIMA NETO, Pedro de; CORREIA, Adriana Nunes; LIMA, Janete Eliza Soares de. Imipramine sensing in pharmaceutical formulations using boron-doped diamond electrode. Journal of Electroanalytical Chemistry, [s.l.], v. 788, p. 118-124, 2017. | pt_BR |
dc.identifier.issn | 1572-6657 | - |
dc.identifier.other | DOI: https://doi.org/10.1016/j.jelechem.2017.01.067 | - |
dc.identifier.uri | http://www.repositorio.ufc.br/handle/riufc/72197 | - |
dc.description.abstract | This paper describes the development of an electroanalytical procedure proposal for the determination of tricyclic antidepressant imipramine (IMP) in commercial pharmaceutical formulations using boron-doped diamond electrode and square-wave voltammetry. The electrochemical oxidation of imipramine was studied in 0.04 mol L−1 Britton-Robinson buffer solution. The voltammetric results showed two well-defined oxidation peaks with potentials of 0.04 V and 0.82 V vs. Ag/AgCl/3 mol L−1 Cl− for peaks 1 and 2, respectively. The effect of the experimental and voltammetric parameters was evaluated and the best performance was obtained in pH 7.4, pulses application frequency of potential of 100 Hz, amplitude of 50 mV and potential increment of 2 mV. Under these conditions, the analytical curves were obtained in the linear range of concentration from 1.73 × 10−7 mol L−1 to 2.53 × 10−6 mol L−1 (r = 0.9984), with detection and quantitation limits 4.35 × 10−8 mol L−1 and 1.45 × 10−7 mol L−1, respectively. The proposed method was applied with success in the determination of IMP in commercial pharmaceutical formulations and validated by comparison with standard method for determination of imipramine. The obtained results were in close agreement, at a 95% confidence level, with those obtained using an official method of the British Pharmacopeia. | pt_BR |
dc.language.iso | en | pt_BR |
dc.publisher | Journal of Electroanalytical Chemistry | pt_BR |
dc.subject | Imipramine | pt_BR |
dc.subject | Boron-doped diamond electrode | pt_BR |
dc.subject | Square-wave voltammetry | pt_BR |
dc.subject | Imipramina | pt_BR |
dc.subject | Eletrodo de diamante dopado com boro | pt_BR |
dc.subject | Voltametria de onda quadrada | pt_BR |
dc.title | Imipramine sensing in pharmaceutical formulations using boron-doped diamond electrode | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
Aparece nas coleções: | DEME - Artigos publicados em revista científica |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
2017_art_plimaneto.pdf | 3,52 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.