Use este identificador para citar ou linkar para este item:
http://repositorio.ufc.br/handle/riufc/69450
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Morais, Ernande Eugenio Campelo | - |
dc.contributor.author | Lima, Francisco Kleber de Araújo | - |
dc.contributor.author | Fonseca, Jean Marcos Lobo da | - |
dc.contributor.author | Castelo Branco, Carlos Gustavo | - |
dc.contributor.author | Machado, Lívia de Araújo | - |
dc.date.accessioned | 2022-11-24T11:40:37Z | - |
dc.date.available | 2022-11-24T11:40:37Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | BRANCO, C. G. C. et al. Providing ancillary services with wind turbine generators based on DFIG with a two-branch static converter. Energies, [s.l], v. 12, n. 13, 2019. DOI: https://doi.org/10.3390/en12132490 | pt_BR |
dc.identifier.issn | 1996-1073 | - |
dc.identifier.uri | http://www.repositorio.ufc.br/handle/riufc/69450 | - |
dc.description.abstract | This work aims to analyze and validate through mathematical modeling and experimental results, in a three-phase three-wire electrical system, the technical viability of a static power converter with a two-level topology with only two controlled branches (2L2B), operating as a grid-side converter (GSC) in a wind turbine generator based on a doubly fed induction generator (DFIG). With this reduced-switches topology, the GSC is able to regulate the DC-link voltage level from the generator back-to-back converter and provide ancillary services of harmonic filtering and reactive power compensation from linear/nonlinear loads connected to the point of common coupling. An 8-kVA experimental prototype was implemented in the laboratory to validate the proposal. The prototype control system was realized using the dSPACE DS1103 PPC Controller Board platform programmed via MATLAB/Simulink. The effectiveness of the proposed system is verified by comparing the results obtained with the 2L2B topology to the ones with the usual two-level three-branch topology. | pt_BR |
dc.language.iso | en | pt_BR |
dc.publisher | Energies | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.subject | Wind power generation | pt_BR |
dc.subject | DFIG | pt_BR |
dc.subject | Ancillary services | pt_BR |
dc.subject | Power quality | pt_BR |
dc.subject | Reduced-Switches topology | pt_BR |
dc.title | Providing ancillary services with wind turbine generators based on DFIG with a two-branch static converter | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
Aparece nas coleções: | DEEL - Artigos publicados em revista científica |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
2019_art_cgcbranco.pdf | 2,31 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.