Use este identificador para citar ou linkar para este item:
http://repositorio.ufc.br/handle/riufc/68055
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Marques, João Alexandre Lôbo | - |
dc.contributor.author | Cortez, Paulo César | - |
dc.contributor.author | Madeiro, João Paulo do Vale | - |
dc.contributor.author | Fong, Simon James | - |
dc.contributor.author | Schlindwein, Fernando Soares | - |
dc.contributor.author | Albuquerque, Victor Hugo Costa de | - |
dc.date.accessioned | 2022-09-05T18:45:04Z | - |
dc.date.available | 2022-09-05T18:45:04Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | CORTEZ, P. C. et al. Automatic cardiotocography diagnostic system based on hilbert transform and adaptive threshold technique. IEEE Acess, vol. 7, p. 73085-73094, 2019. DOI: 10.1109/ACCESS.2018.2877933 | pt_BR |
dc.identifier.issn | 2169-3536 | - |
dc.identifier.uri | http://www.repositorio.ufc.br/handle/riufc/68055 | - |
dc.description.abstract | The visual analysis of cardiotocographic examinations is a very subjective process. The accurate detection and segmentation of the fetal heart rate (FHR) features and their correlation with the uterine contractions in time allow a better diagnostic and the possibility of anticipation of many problems related to fetal distress. This paper presents a computerized diagnostic aid system based on digital signal processing techniques to detect and segment changes in the FHR and the uterine tone signals automatically. After a pre-processing phase, the FHR baseline detection is calculated. An auxiliary signal called detection line is proposed to support the detection and segmentation processes. Then, the Hilbert transform is used with an adaptive threshold for identifying fiducial points on the fetal and maternal signals. For an antepartum (before labor) database, the positive predictivity value (PPV) is 96.80% for the FHR decelerations, and 96.18% for the FHR accelerations. For an intrapartum (during labor) database, the PPV found was 91.31% for the uterine contractions, 94.01% for the FHR decelerations, and 100% for the FHR accelerations. For the whole set of exams, PPV and SE were both 100% for the identification of FHR DIP II and prolonged decelerations. | pt_BR |
dc.language.iso | en | pt_BR |
dc.publisher | IEEE Acess | pt_BR |
dc.subject | Fetal heart rate (FHR) | pt_BR |
dc.subject | Hilbert transform | pt_BR |
dc.subject | Uterine contractions (UC) | pt_BR |
dc.subject | Cardiotocografia | pt_BR |
dc.subject | Frequência cardíaca fetal | pt_BR |
dc.subject | Cardiotocography (CTG) | pt_BR |
dc.subject | Transformada de Hilbert | pt_BR |
dc.subject | Contração uterina | pt_BR |
dc.title | Automatic cardiotocography diagnostic system based on hilbert transform and adaptive threshold technique | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
Aparece nas coleções: | DETE - Artigos publicados em revista científica |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
2019_art_pccortez.pdf | 5,93 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.