Use este identificador para citar ou linkar para este item: http://repositorio.ufc.br/handle/riufc/68055
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorMarques, João Alexandre Lôbo-
dc.contributor.authorCortez, Paulo César-
dc.contributor.authorMadeiro, João Paulo do Vale-
dc.contributor.authorFong, Simon James-
dc.contributor.authorSchlindwein, Fernando Soares-
dc.contributor.authorAlbuquerque, Victor Hugo Costa de-
dc.date.accessioned2022-09-05T18:45:04Z-
dc.date.available2022-09-05T18:45:04Z-
dc.date.issued2019-
dc.identifier.citationCORTEZ, P. C. et al. Automatic cardiotocography diagnostic system based on hilbert transform and adaptive threshold technique. IEEE Acess, vol. 7, p. 73085-73094, 2019. DOI: 10.1109/ACCESS.2018.2877933pt_BR
dc.identifier.issn2169-3536-
dc.identifier.urihttp://www.repositorio.ufc.br/handle/riufc/68055-
dc.description.abstractThe visual analysis of cardiotocographic examinations is a very subjective process. The accurate detection and segmentation of the fetal heart rate (FHR) features and their correlation with the uterine contractions in time allow a better diagnostic and the possibility of anticipation of many problems related to fetal distress. This paper presents a computerized diagnostic aid system based on digital signal processing techniques to detect and segment changes in the FHR and the uterine tone signals automatically. After a pre-processing phase, the FHR baseline detection is calculated. An auxiliary signal called detection line is proposed to support the detection and segmentation processes. Then, the Hilbert transform is used with an adaptive threshold for identifying fiducial points on the fetal and maternal signals. For an antepartum (before labor) database, the positive predictivity value (PPV) is 96.80% for the FHR decelerations, and 96.18% for the FHR accelerations. For an intrapartum (during labor) database, the PPV found was 91.31% for the uterine contractions, 94.01% for the FHR decelerations, and 100% for the FHR accelerations. For the whole set of exams, PPV and SE were both 100% for the identification of FHR DIP II and prolonged decelerations.pt_BR
dc.language.isoenpt_BR
dc.publisherIEEE Acesspt_BR
dc.subjectFetal heart rate (FHR)pt_BR
dc.subjectHilbert transformpt_BR
dc.subjectUterine contractions (UC)pt_BR
dc.subjectCardiotocografiapt_BR
dc.subjectFrequência cardíaca fetalpt_BR
dc.subjectCardiotocography (CTG)pt_BR
dc.subjectTransformada de Hilbertpt_BR
dc.subjectContração uterinapt_BR
dc.titleAutomatic cardiotocography diagnostic system based on hilbert transform and adaptive threshold techniquept_BR
dc.typeArtigo de Periódicopt_BR
Aparece nas coleções:DETE - Artigos publicados em revista científica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2019_art_pccortez.pdf5,93 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.