Use este identificador para citar ou linkar para este item: http://repositorio.ufc.br/handle/riufc/66794
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorLima Neto, Pedro de-
dc.contributor.authorFarias, Jesualdo Pereira-
dc.contributor.authorHerculano, Luís Flávio Gaspar-
dc.contributor.authorMiranda, Hélio Cordeiro de-
dc.contributor.authorAraújo, Walney Silva-
dc.contributor.authorJorcin, Jean-Baptiste-
dc.contributor.authorPébère, Nadine-
dc.date.accessioned2022-06-29T12:14:39Z-
dc.date.available2022-06-29T12:14:39Z-
dc.date.issued2008-
dc.identifier.citationLIMA-NETO, Pedro de et al. Determination of the sensitized zone extension in welded AISI 304 stainless steel using non-destructive electrochemical techniques. Corros­i­on­ Sci­e­n­ce, [s.l.], v. 50, n. 4, p. 1149-1155, 2008.pt_BR
dc.identifier.issn0010-938X-
dc.identifier.urihttp://www.repositorio.ufc.br/handle/riufc/66794-
dc.description.abstractExtension of sensitized zone (SZ) in welded AISI 304 stainless steel was determined by two non-destructive electrochemical tests: double loop electrochemical potentiokinetic reactivation technique (DLEPR) and local electrochemical impedance spectroscopy (LEIS). Welding was carried out using the shielded metal arc with two selected welding energies: the first one (0.7kJmm¡1) does not promote the sensitization of the 304 steel and it constitutes the reference sample and the second one (2.2kJmm¡1) which leads to the precipitation of chromium carbides in the grain boundaries after the welding process. The non-destructive DLEPR and LEIS tests allowed the length of the SZ to be determined and a good agreement between the two techniques and the microstructure of the two welded samples was shown. The presence of an inductive loop on the local impedance diagrams seems to reflect a galvanic coupling between the weld string (anode) and the welded stainless steel plates (cathode) which will be very prejudicial to a good corrosion resistance of the welded system. The results showed that the two electrochemical tests could be applied in practical cases in industrial field.pt_BR
dc.language.isoenpt_BR
dc.publisherCorros­i­on­ Sci­e­n­cept_BR
dc.subjectA. Stainless steelpt_BR
dc.subjectB. EISpt_BR
dc.subjectB. SEMpt_BR
dc.subjectC. Weldingpt_BR
dc.subjectC. Intergranular corrosionpt_BR
dc.titleDetermination of the sensitized zone extension in welded AISI 304 stainless steel using non-destructive electrochemical techniquespt_BR
dc.typeArtigo de Periódicopt_BR
Aparece nas coleções:DEMM - Artigos publicados em revista científica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2008_art_plima-neto.pdf1,25 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.