Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.ufc.br/handle/riufc/63877
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Girão, Daniel de Castro | - |
dc.contributor.author | Béreš, Miloslav | - |
dc.contributor.author | Jardini, André Luiz | - |
dc.contributor.author | Maciel Filho, Rubens | - |
dc.contributor.author | Silva, Cleiton Carvalho | - |
dc.contributor.author | Siervo, Abner de | - |
dc.contributor.author | Abreu, Hamilton Ferreira Gomes de | - |
dc.contributor.author | Araújo, Walney Silva | - |
dc.date.accessioned | 2022-02-10T18:11:25Z | - |
dc.date.available | 2022-02-10T18:11:25Z | - |
dc.date.issued | 2020 | - |
dc.identifier.citation | GIRÃO, Daniel de Castro; BÉREŠ, Miloslav; JARDINI, André Luiz; MACIEL FILHO, Rubens; SILVA, Cleiton Carvalho; SIERVO, Abner de; ABREU, Hamilton Ferreira Gomes de; ARAÚJO, Walney Silva. An assessment of biomedical CoCrMo alloy fabricated by direct metal laser sintering technique for implant applications. Materials Science and Engineering: C, v. 107,n. 110305, fev. 2020. | pt_BR |
dc.identifier.issn | 0928-4931 | - |
dc.identifier.other | https://doi.org/10.1016/j.msec.2019.110305 | - |
dc.identifier.uri | http://www.repositorio.ufc.br/handle/riufc/63877 | - |
dc.description.abstract | CoCrMo alloys have been used for several decades in implantable devices due to their favourable mechanical properties, low wear rate in addition to good biocompatibility and high corrosion resistance. These alloys are conventionally produced via casting and/or forging route, however additive manufacturing techniques being recently employed in their fabrication. In this work, CoCrMo samples were produced by direct metal laser sintering additive manufacturing process. The microstructure and surface composition were examined employing scanning electron microscopy, X-ray diffraction and X-ray photoelectron spectroscopy (XPS). The corrosion resistance was measured in 0.14 M sodium chloride solution and in phosphate buffered solution (PBS) both with and without addition of albumin at pH 7.4 and 37 °C. For this, potentiodynamic tests in addition to electrochemical impedance spectroscopy were employed. The studied CoCrMo alloy exhibits a good corrosion resistance in solutions tested being the highest in PBS solution without albumin addition. The XPS analysis showed that the passive film composition and its thickness are not modified by the adsorbed layer. Microstructural analysis revealed occurrence of strain-induced martensitic transformation. | pt_BR |
dc.language.iso | pt_BR | pt_BR |
dc.publisher | Elsevier B.V. or its licensors or contributors. ScienceDirect ® | pt_BR |
dc.subject | CoCrMo alloy | pt_BR |
dc.subject | Corrosion resistance | pt_BR |
dc.subject | Simulated body fluids | pt_BR |
dc.subject | Additive manufacturing | pt_BR |
dc.subject | Direct metal laser sintering | pt_BR |
dc.title | An assessment of biomedical CoCrMo alloy fabricated by direct metal laser sintering technique for implant applications | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.title.en | An assessment of biomedical CoCrMo alloy fabricated by direct metal laser sintering technique for implant applications | pt_BR |
Aparece en las colecciones: | DEMM - Artigos publicados em revista científica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
2020_art_ddecgirao.pdf | 3,04 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.