Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ufc.br/handle/riufc/44442
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorMoreira, Adson Bezerra-
dc.contributor.authorBarros, Tárcio André dos Santos-
dc.contributor.authorTeixeira, Vanessa Siqueira de Castro-
dc.contributor.authorSouza, Ramon Rodrigues de-
dc.contributor.authorPaula, Marcelo Vinicius de-
dc.contributor.authorRuppert Filho, Ernesto-
dc.date.accessioned2019-08-05T12:23:43Z-
dc.date.available2019-08-05T12:23:43Z-
dc.date.issued2019-
dc.identifier.citationMOREIRA, A.B. (2019)pt_BR
dc.identifier.urihttp://www.repositorio.ufc.br/handle/riufc/44442-
dc.descriptionMoreira, A.B.; BARROS, TARCIO ANDRE DOS SANTOS ; TEIXEIRA, VANESSA SIQUEIRA DE CASTRO ; SOUZA, RAMON R. ; DE PAULA, MARCELO V. ; FILHO, ERNESTO RUPPERT . Control of powers for wind power generation and grid current harmonics filtering from doubly fed induction generator: comparison of two strategies. IEEE Access, v. 7, p. 1-1, 2019.pt_BR
dc.description.abstractTwo strategies for wind power systems that simultaneously adjust the powers generation from doubly fed induction generator and achieves grid currents harmonic filtering are presented in this paper. The harmonic mitigation function is developed by algorithms proposed for compensating harmonics from the grid side converter. The quality of power is substantially enhanced. The generator side converter regulates the active and reactive powers that are supplied to the electric grid by the stator flux oriented control. This paper presents a novel control system for power generation and electric grid harmonic compensation, which is described and validated through comparison with other strategies. A harmonic filtering behavior analysis for some operation points using the novel strategy is presented. The proposed system efficiency is verified through simulation and experimental results. The grid current THD when none of the proposed strategies are applied is 17.21%. The THD is reduced to 5.68% when strategy 1 is applied. When strategy 2 is used the THD is decreased to 3.18%.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectControllers designpt_BR
dc.subjectDoubly fed induction generatorpt_BR
dc.subjectIntegrated active filterpt_BR
dc.subjectHarmonic filteringpt_BR
dc.subjectPower qualitypt_BR
dc.subjectWind power generationpt_BR
dc.titleControl of Powers for Wind Power Generation and Grid Current Harmonics Filtering From Doubly Fed Induction Generator: Comparison of Two Strategiespt_BR
dc.typeArtigo de Periódicopt_BR
dc.title.enControl of Powers for Wind Power Generation and Grid Current Harmonics Filtering From Doubly Fed Induction Generator: Comparison of Two Strategiespt_BR
Aparece en las colecciones: CSOBRAL - Artigos publicados em revistas científicas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
2019_artg_abmoreira.pdf8,66 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.