Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ufc.br/handle/riufc/18184
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorVasques, Paulo Henrique Diógenes-
dc.contributor.authorAlves, Mayara Maia-
dc.contributor.authorAquino, Ranniere Gurgel Furtado de-
dc.contributor.authorTorres, Roberto Vitor Almeida-
dc.contributor.authorBezerra, José Lucas Martins-
dc.contributor.authorBrasileiro, Luis Porto-
dc.contributor.authorPinheiro, Luiz Gonzaga Porto-
dc.date.accessioned2016-07-06T14:20:13Z-
dc.date.available2016-07-06T14:20:13Z-
dc.date.issued2015-
dc.identifier.citationVASQUES, Paulo Henrique Diógenes et al. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer. Acta Cirúrgica Brasileira, São Paulo,v. 30, n. 11, p. 785-790, 2015.pt_BR
dc.identifier.issnPrint version 0102-8650-
dc.identifier.issnOn-line version 1678-2674-
dc.identifier.urihttp://www.repositorio.ufc.br/handle/riufc/18184-
dc.description.abstractPURPOSE: To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. METHODS: Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. RESULTS: The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. CONCLUSION: Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy.pt_BR
dc.language.isoenpt_BR
dc.publisherActa Cirúrgica Brasileirapt_BR
dc.subjectNeoplasias da Mamapt_BR
dc.subjectHemossiderinapt_BR
dc.subjectTecnéciopt_BR
dc.titleComparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancerpt_BR
dc.typeArtigo de Periódicopt_BR
Aparece en las colecciones: DCIR - Artigos publicados em revista científica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
2015_art_phdvasques.pdf625,08 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.