Use este identificador para citar ou linkar para este item:
http://repositorio.ufc.br/handle/riufc/25528
Tipo: | Artigo de Periódico |
Título: | Evaluation of clinical and laboratory parameters used in the identification of index cases for genetic screening of familial hypercholesterolemia in Brazil |
Autor(es): | Silva, Pamela R. S. Jannes, Cinthia E. Oliveira, Theo G. M. Miname, Marcio H. Rocha, Viviane Z. Chacra, Ana Paula Gurgel, Maria Helane C. Montenegro, Renan M. Rodrigues Sobrinho, Carlos Roberto M. Moreira, Annie Seixas Bello Assad, Marcelo H. V. Pinto, Marina R. C. Tada, Mauricio Teruo Santos, Raul D. Pereira, Alexandre C. Krieger, Jose E. |
Palavras-chave: | Hiperlipoproteinemia Tipo II;Colesterol;Hipercolesterolemia |
Data do documento: | 2017 |
Instituição/Editor/Publicador: | Atherosclerosis |
Citação: | SILVA, P. R. S. et al. Evaluation of clinical and laboratory parameters used in the identification of index cases for genetic screening of familial hypercholesterolemia in Brazil. Atherosclerosis, Amsterdam, v. 263, p. 257-262, 2017. |
Abstract: | Background and aims: There is controversy on the accuracy of different diagnostic criteria for familial hypercholesterolemia (FH). The aim of this study is to assess the performance of different clinical criteria used to identify individuals for FH genetic cascade screening in Brazil. Methods: All index cases (IC) registered in the Hipercol Brasil program between 2011 and 2016 were analyzed. Inclusion criteria were age 18 years and elevated LDL-cholesterol (LDL-C) levels, with a conclusive result in the genetic test, whether positive or negative. Initially, we tested the multivariable association between clinical and laboratory markers and the presence of an FH causing mutation. Then, we analyzed sensitivity, specificity, positive and negative predictive values for the LDL-C quartile distribution, LDL-C as a continuous variable, as well as the performance measures for the Dutch Lipid Clinic Network (DLCN) score to identify a mutation. Results: Overall, 753 ICs were included and an FH causing mutation was found in 34% (n ¼ 257) of the subjects. After multivariable analysis, LDL-C as a continuous variable, tendon xanthomas and corneal arcus were independently associated with the presence of FH mutations. LDL-C values 230 mg/dL (5.9 mmol/L) had the best tradeoff between sensitivity and specificity to diagnose a mutation. The DLCN score presented a better performance than LDL-C to identify a mutation, area under the ROC curve were 0.744 (95% CI: 0.704e0.784) and 0.730 (95% CI: 0.687e0.774), respectively, p¼0.014. Conclusions: In our population, LDL 230 mg/dL is a feasible criterion to indicate ICs to genetic testing. |
URI: | 0021-9150 http://www.repositorio.ufc.br/handle/riufc/25528 |
ISSN: | 1879-1484 |
Aparece nas coleções: | DMC - Artigos publicados em revistas científicas |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
2017_art_prssilva.pdf | 495,5 kB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.